Conair MPW Guida Utente Pagina 58

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 57
Corporate Office: 724.584.5500 Instant Access 24/7 (Parts and Service): 800.458.1960 Parts and Service: 814.437.6861
53
Problem PossibleCause Solution
Erratictemperature
control
Lowcoolantflowthroughevaporator Adjustflowtoproperlevel
Intermittentoverloadingofchillercapacity Checktomakesurechillerisproperlysized
forprocessload
Hotgasbypassvalve Contactrefrigerationservicetechnician
Temperaturesensor Replaceiffaulty
Insufficientcooling
(temperature
continuestorise
abovesetpoint)
Processloadtoohigh Checktomakesurechillerisproperlysized
forprocessload
Coolantflowthrough evaporatortoohighorlow Adjustflowtoproperlevel
Insufficientcondensercooling See“HighRefrigerantPressure”
Hotgasbypassvalvestuckopen Contactrefrigerationservicetechnician
Refrigerationcircuitproblem Contactrefrigerationservicetechnician
Temperaturesensor Replaceiffaulty
Drawings
Wehavepreparedacustomsetofdrawingsforyourunitandplacedtheminsidethecontrol
panelpriortoshipment.Pleaserefertothesedrawingswhentroubleshooting,servicing,and
installingtheunit.Ifyoucannotfindthesedrawingsorwishtohaveadditional copies,please
contactourServiceDepartmentandreferencetheserialnumberofyourunit.
ContactConairPartsandServiceat18004581960(intheUnitedStates)or18144376861
(international).Press1forServiceand2forParts.

Vedere la pagina 57
1 2 ... 53 54 55 56 57 58 59 60

Commenti su questo manuale

Nessun commento