5-2 l Maintenance
Preventative Maintenance
Checklist
The HTC process air heater requires little maintenance. We recommend the fol-
lowing maintenance schedule and tasks.
Whenever you change material or process
Change the HTC setpoint if it must be changed.
Daily or weekly as needed
Inspect the inlet and outlet hoses.
Tighten the hose clamps if loose. Replace the hose if worn or damaged.
Inspect the filter (if equipped).
Clean or replace the filter as necessary.
Monthly or as often as needed
Inspect the main power wires, heater wires and conduit, and RTD
probe wires for damage and wear.
Replace any damaged or worn wire or conduit.
Check for any damage to the control panel.
Replace if damaged.
Check for damage to the heater box.
Replace if damaged.
Clean dirt from exterior surfaces with a cloth dampened with water.